319 research outputs found

    Potential of Argo drifters for estimating biological production within the water column

    Get PDF
    Argo drifters provide information of the vertical structure in the water column and have a potential for the improvement of understanding phytoplankton primary production and biogeochemical cycles in combination with ocean color satellite data, which can obtain the horizontal distribution of phytoplankton biomass in the surface layer. Our examples show that using Argo drifters with satellite-measured horizontal distribution of phytoplankton biomass at the sea surface allow an improved understanding of the development of the spring bloom. The other possible uses of Argo drifter are discussed

    Experimental Verification of Modal Identification of a High-rise Building Using Independent Component Analysis

    Get PDF
    Abstract Independent component analysis is one of the linear transformation methods based the techniques for separating blind sources from the output signals of the system. Recently, the method has been analytically applied to the identification of mode shapes and modal responses from the output signal of structures. This study aims to experimentally validate the blind source separation using ICA method and propose a novel method for identification of the modal parameters from the decomposed modal responses. The result of the experimental testing on the three-story steel scale model shows that the mode shapes obtained by ICA method are in good agreement with those by the analytical and peak-picking method in the frequency domain. Based on the robust mathematical model, ICA can calculate the natural frequency and damping ratio effectively using the probability distribution function of the instantaneous natural frequency determined by Hilbert transform of the decomposed modal responses and the change in the output covariance. Finally, the validity of the proposed method paves the way for more effective output-only modal identification for assessment of existing steel-concrete buildings

    Epidural cement leakage through pedicle violation after balloon kyphoplasty causing paraparesis in osteoporotic vertebral compression fractures - a report of two cases

    Get PDF
    Kyphoplasty is advantageous over vertebroplasty in terms of better kyphosis correction and diminished risk of cement extravasations. Literature described cement leakage causing neurological injury mainly after vertebroplasty procedure; only a few case reports show cement leakage with kyphoplasty without neurological injury or proper cause of leakage. We present a report two cases of osteoporotic vertebral compression fracture treated with kyphoplasty and developed cement leakage causing significant neurological injury. In both cases CT scan was the diagnostic tool to identify cause of cement leakage. CT scan exhibited violation of medial pedicle wall causing cement leakage in the spinal canal. Both patients displayed clinical improvement after decompression surgery with or without instrumentation. Retrospectively looking at stored fluoroscopic images, we found that improper position of trocar in AP and lateral view simultaneously while taking entry caused pedicle wall violation. We suggest not to cross medial pedicle wall in AP image throughout the entire procedure and keeping the trocar in the center of pedicle in lateral image would be the most important precaution to prevent such complication. Our case reports adds the neurological complications with kyphoplasty procedure and suggested that along with other precautions described in the literature, entry with trocar along the entire procedure keeping the oval shape of pedicle in mind (under C-arm) will probably help to prevent such complications

    Small non-coding RNA profiling and the role of piRNA pathway genes in the protection of chicken primordial germ cells

    Get PDF
    This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited.Background Genes, RNAs, and proteins play important roles during germline development. However, the functions of non-coding RNAs (ncRNAs) on germline development remain unclear in avian species. Recent high-throughput techniques have identified several classes of ncRNAs, including micro RNAs (miRNAs), small-interfering RNAs (siRNAs), and PIWI-interacting RNAs (piRNAs). These ncRNAs are functionally important in the genome, however, the identification and annotation of ncRNAs in a genome is challenging. The aim of this study was to identify different types of small ncRNAs particularly piRNAs, and the role of piRNA pathway genes in the protection of chicken primordial germ cells (PGCs). Results At first, we performed next-generation sequencing to identify ncRNAs in chicken PGCs, and we performed ab initio predictive analysis to identify putative piRNAs in PGCs. Then, we examined the expression of three repetitive sequence-linked piRNAs and 14 genic-transcript-linked piRNAs along with their linked genes using real-time PCR. All piRNAs and their linked genes were highly expressed in PGCs. Subsequently, we knocked down two known piRNA pathway genes of chicken, PIWI-like protein 1 (CIWI) and 2 (CILI), in PGCs using siRNAs. After knockdown of CIWI and CILI, we examined their effects on the expression of six putative piRNA-linked genes and DNA double-strand breakage in PGCs. The knockdown of CIWI and CILI upregulated chicken repetitive 1 (CR1) element and RAP2B, a member of RAS oncogene family, and increased DNA double-strand breakage in PGCs. Conclusions Our results increase the understanding of PGC-expressed piRNAs and the role of piRNA pathway genes in the protection of germ cells

    Ferromagnetic properties of SrRuO3 thin films deposited on the spin-triplet superconductor Sr2RuO4

    Get PDF
    We report magnetic properties of epitaxial thin films of the itinerant ferromagnet SrRuO3 deposited on the cleaved ab surface of the spin-triplet superconductor Sr2RuO4. The films exhibit ferromagnetic transition near 160 K as in the bulk SrRuO3, although the films are under 1.7% compressive strain. The observed magnetization is even higher than that of the bulk SrRuO3. In addition, we newly found that the magnetization relaxation after field removal is strongly anisotropic: two relaxation processes are involved when magnetic domains are aligned along the ab-plane.Comment: 6 pages, 3 figures This paper is accepted for publication in the proceedings of ICM 2015 (Physics Procedia

    Percutaneous Needle Decompression during Laparoscopic Gastric Surgery: A Simple Alternative to Nasogastric Decompression

    Get PDF
    Laparoscopic gastric surgeries are routinely performed with use of a nasogastric tube to decompress the upper gastrointestinal tract. A distended upper gastrointestinal tract can complicate successful laparoscopic gastric surgery as the distention compromises not only the visual field but also the laparoscopic manipulation of the stomach. Since nasogastric intubation is not without risks, we have attempted laparoscopic-assisted gastric cancer surgeries without nasogastric tubes. In this article we describe a simple method of aspirating gastric contents using a 9 cm long 19-gauge needle inserted percutaneously during laparoscopic-assisted gastrectomy. First, a 9 cm long 19-gauge disposable needle was introduced through the abdominal wall. This needle was then introduced to the stomach through the anterior wall and the stomach gases and fluids were aspirated by connecting the needle to suction. Thus, a collapsed upper gastrointestinal tract was easily obtained. We performed this procedure instead of nasogastric decompression on twenty-two patients with gastric cancer who underwent laparoscopic-assisted distal subtotal gastrectomy with lymph node dissection. The results were good with only one patient experiencing wound infection (4.5%) and one patient with postoperative acalculus cholecystitis (4.5%). There were no patients with either intraabdominal infection or anastomotic leakage and none of the patients needed postoperative nasogastric decompression, except the patient who experienced acaculus cholecystitis. Percutaneous needle aspiration is a very simple and efficient technique with little risk of postoperative complications. It can be used as an alternative to nasogastric tube decompression of the gastrointestinal tract for laparoscopic-assisted gastrectomy
    corecore